Programmable Relays (Micro PLC)

Programmable Relays (Micro PLC)

Programmable Relays (Micro PLC)

To enable a simple installation into your device, we offer our single board computers for HMI applications as matched turnkey systems including touch display and housing. The rear mount HMI is installed from the inside of the front panel and easily fastened with screws. We are happy to advise you on the selection of suitable sealings or scratch-resistant cover foils.
  • PR-24DC-DAI-RTA

    PR-24DC-DAI-RTA

    CPU Module
    • Power:
    • 12-24V DC
    • Inputs:
    • 6 Digital, 6 Digital/Analog (0‑10V), 2 Analog (0-20mA)
    • Outputs:
    • 6 Relay, 2 Transistor PNP, 1 Analog (0-10V or 0-20mA)
    • Memory:
    • 1024 Blocks/13k Steps
    • Expansion:
    • 16 modules (PR-E)
    • Communication:
    • RS232 Program Port, RS485 Port (with PRO-RS485), RS485 Port (with PR-E-RS485), Built-in RS485 Port
  • PR-24DC-DA-R

    PR-24DC-DA-R

    CPU Module
    • Power:
    • 12-24V DC
    • Inputs:
    • 8 Digital, 6 Digital/Analog (0‑10V)
    • Outputs:
    • 10 Relay
    • Memory:
    • 1024 Blocks/13k Steps
    • Expansion:
    • 16 modules (PR-E)
    • Communication:
    • RS232 Program Port, RS485 Port (with PRO-RS485), RS485 Port (with PR-E-RS485), Built-in RS485 Port
  • PR-24AC-R

    PR-24AC-R

    CPU Module
    • Power:
    • 110-240V AC
    • Inputs:
    • 14 Digital
    • Outputs:
    • 10 Relay
    • Memory:
    • 1024 Blocks/13k Steps
    • Expansion:
    • 16 modules (PR-E)
    • Communication:
    • RS232 Program Port, RS485 Port (with PRO-RS485), RS485 Port (with PR-E-RS485), Built-in RS485 Port
  • PR-18DC-DA-RT

    PR-18DC-DA-RT

    CPU Module
    • Power:
    • 12-24V DC
    • Inputs:
    • 6 Digital, 6 Digital/Analog (0‑10V)
    • Outputs:
    • 4 Relay, 2 Transistor PNP
    • Memory:
    • 1024 Blocks/13k Steps
    • Expansion:
    • 16 modules (PR-E)
    • Communication:
    • RS232 Program Port, RS485 Port (with PRO-RS485), RS485 Port (with PR-E-RS485)
  • PR-18DC-DA-R

    PR-18DC-DA-R

    CPU Module
    • Power:
    • 12-24V DC
    • Inputs:
    • 6 Digital, 6 Digital/Analog (0‑10V)
    • Outputs:
    • 6 Relay
    • Memory:
    • 1024 Blocks/13k Steps
    • Expansion:
    • 16 modules (PR-E)
    • Communication:
    • RS232 Program Port, RS485 Port (with PRO-RS485), RS485 Port (with PR-E-RS485)
  • PR-18AC-R

    PR-18AC-R

    CPU Module
    • Power:
    • 110-240V AC
    • Inputs:
    • 12 Digital
    • Outputs:
    • 6 Relay
    • Memory:
    • 1024 Blocks/13k Steps
    • Expansion:
    • 16 modules (PR-E)
    • Communication:
    • RS232 Program Port, RS485 Port (with PRO-RS485), RS485 Port (with PR-E-RS485)
  • PR-14DC-DA-R

    PR-14DC-DA-R

    CPU Module
    • Power:
    • 12-24V DC
    • Inputs:
    • 4 Digital, 6 Digital/Analog (0‑10V)
    • Outputs:
    • 4 Relay
    • Memory:
    • 512 Blocks/5k Steps
    • Expansion:
    • 16 modules (PR-E)
    • Communication:
    • RS232 Program Port, RS485 Port (with PRO-RS485), RS485 Port (with PR-E-RS485), Built-in RS485 Port
  • PR-14AC-R

    PR-14AC-R

    CPU Module
    • Power:
    • 110-240V AC
    • Inputs:
    • 10 Digital
    • Outputs:
    • 4 Relay
    • Memory:
    • 512 Blocks/5k Steps
    • Expansion:
    • 16 modules (PR-E)
    • Communication:
    • RS232 Program Port, RS485 Port (with PRO-RS485), RS485 Port (with PR-E-RS485), Built-in RS485 Port
  • PR-E-AQ-VI

    PR-E-AQ-VI

    Expansion module
    • Power:
    • 12-24V DC
    • Outputs:
    • 2 Analog (0-10V or 0-20mA)
    • Сompatibility:
    • PR-14, PR-18, PR-24
  • PR-12AC-R-E

    PR-12AC-R-E

    CPU Module
    • Power:
    • 110-240V AC
    • Inputs:
    • 8 Digital
    • Outputs:
    • 4 Relay
    • Memory:
    • 64 Blocks only FBD
    • Expansion:
    • None
    • Communication:
    • RS232 Program Port, RS485 Port (with PRO-RS485)
  • PR-6DC-DA-R

    PR-6DC-DA-R

    CPU Module
    • Power:
    • 12-24V DC
    • Inputs:
    • 4 Digital/Analog (0‑10V)
    • Outputs:
    • 2 Relay
    • Memory:
    • 64 Blocks only FBD
    • Expansion:
    • None
    • Communication:
    • RS232 Program Port, RS485 Port (with PRO-RS485)
  • PR-6AC-R

    PR-6AC-R

    CPU Module
    • Power:
    • 110-240V AC
    • Inputs:
    • 4 Digital
    • Outputs:
    • 2 Relay
    • Memory:
    • 64 Blocks only FBD
    • Expansion:
    • None
    • Communication: